Dokument: Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples

Titel:Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples
URL für Lesezeichen:https://docserv.uni-duesseldorf.de/servlets/DocumentServlet?id=73511
URN (NBN):urn:nbn:de:hbz:061-20260608-105922-2
Kollektion:Publikationen
Sprache:Englisch
Dokumententyp:Wissenschaftliche Texte » Artikel, Aufsatz
Medientyp:Text
Autoren: Eberhardt, Kirsten Alexandra [Autor]
Frickmann, Hagen [Autor]
Hahn, Andreas [Autor]
Loderstädt, Ulrike [Autor]
Schwarz, Norbert Georg [Autor]
Hagen, Ralf Matthias [Autor]
Dateien:
[Dateien anzeigen]Adobe PDF
[Details]317 KB in einer Datei
[ZIP-Datei erzeugen]
Dateien vom 08.06.2026 / geändert 08.06.2026
Stichwörter:schistosomiasis , Schistosoma mansoni complex , pan-trematode PCR , diagnostic accuracy , Schistosoma haematobium complex , test comparison
Beschreibung:Background: Schistosoma spp. are trematodes occurring in tropical endemic areas but can be imported to non-endemic regions as causes of travel-associated infections. In this study, two pan-trematode-specific real-time PCR assays were evaluated for their diagnostic sensitivity in detecting Schistosoma spp. DNA in diagnostic human samples. Methods: Two previously described pan-trematode-specific real-time PCR assays were comparatively assessed using diagnostic samples containing DNA of either the S. haematobium complex or the S. mansoni complex, as confirmed by Schistosoma species complex-specific real-time PCR. Results: Out of a total of 655 samples containing Schistosoma spp. DNA, positive signals in at least one of the two pan-trematode real-time PCR assays were recorded for 17 (2.6%) nucleic acid extractions. Although sensitivity was in the >90% range for stool samples, only a few individual blood plasma and serum samples, and none of the Schistosoma spp. DNA-containing tissue or urine samples, tested positive by pan-trematode PCR. The lower sensitivity of pan-trematode PCR compared with Schistosoma spp.-specific PCR was semi-quantitatively confirmed by higher cycle threshold (Ct) values in the former. When comparing samples with concordant versus discordant positive results for Schistosoma spp.-specific and pan-trematode PCR, Ct values of the Schistosoma spp.-specific PCR were lower in concordantly positive samples than in discordantly positive samples. Conclusions: While the assessed pan-trematode PCR assays showed insufficient sensitivity as screening tools for blood plasma, blood serum, tissue, and urine samples from individuals with suspected schistosomiasis, they were sufficiently sensitive when applied to stool samples, in which substantial amounts of target DNA, as indicated by low Ct values in the Schistosoma species complex-specific real-time PCR assays, can be expected. For screening for Schistosoma spp. DNA in sample materials other than stool, the use of highly sensitive target-specific PCR remains necessary.
Rechtliche Vermerke:Originalveröffentlichung:
Frickmann, H., Hahn, A., Eberhardt, K. A., Loderstädt, U., Schwarz, N. G., & Hagen, R. M. (2026). Matrix-Dependent Sensitivity of Two Pan-Trematode PCR Assays for Detecting Schistosoma spp. in Clinical Human Samples. Infectious Disease Reports, 18(2), Article 27. https://doi.org/10.3390/idr18020027
Lizenz:Creative Commons Lizenzvertrag
Dieses Werk ist lizenziert unter einer Creative Commons Namensnennung 4.0 International Lizenz
Fachbereich / Einrichtung:Medizinische Fakultät
Dokument erstellt am:08.06.2026
Dateien geändert am:08.06.2026
english
Benutzer
Status: Gast
Aktionen