Dokument: Critical flicker fusion frequency: confounders and caveats

Titel:Critical flicker fusion frequency: confounders and caveats
URL für Lesezeichen:https://docserv.uni-duesseldorf.de/servlets/DocumentServlet?id=72497
URN (NBN):urn:nbn:de:hbz:061-20260309-142317-5
Kollektion:Publikationen
Sprache:Englisch
Dokumententyp:Wissenschaftliche Texte » Artikel, Aufsatz
Medientyp:Text
Autoren: Muth, Thomas [Autor]
Schipke, Jochen D. [Autor]
Dreyer, Sven [Autor]
Brebeck, Anne-Kathrin [Autor]
Dateien:
[Dateien anzeigen]Adobe PDF
[Details]809,5 KB in einer Datei
[ZIP-Datei erzeugen]
Dateien vom 09.03.2026 / geändert 09.03.2026
Stichwörter:Critical flicker fusion frequency , Oxygen , Lighting , Age , Divers , Nitrogen
Beschreibung:Introduction
Critical flicker fusion frequency (cFFF) measures visual perception, with higher values indicating better performance. It is widely used to assess the effects of breathing gases in diving and hyperbaric environments.

Aim
Identify confounders explaining inconsistent cFFF study results.

Methods
Four experiments using a manual flicker device in volunteers with healthy eyes: 1. cFFF was measured in 174 recreational divers to examine demographic effects. 2. One male diver was tested daily over 85 days. 3. In 28 divers, cFFF was measured before and after 5 min of normobaric oxygen. 4. In 24 divers, cFFF was tested with and without diving masks, plus a condition with diagonal flicker light on the mask.

Results
1. Mean cFFF: 39.2 ± 5.1 Hz; decreased with age (p < 0.001), no gender/BMI effect. 2. Mean: 43.4 ± 2.1 Hz; stable across lighting. 3. Thresholds differed by frequency order; minimal O₂ effect. 4. Masks had no effect, but diagonal light reduced cFFF (p < 0.01).

Conclusion
cFFF varied by 13% across divers and 5% in a single diver. Age and observer-light geometry influenced results. Oxygen had minor impact. Findings support using age-specific norms and considering perceptual confounders in diving research.
Rechtliche Vermerke:Originalveröffentlichung:
Muth, T., Schipke, J., Brebeck, A.-K., & Dreyer, S. (2025). Critical flicker fusion frequency: confounders and caveats. European Journal of Applied Physiology, 126(2), 725–734. https://doi.org/10.1007/s00421-025-05935-7
Lizenz:Creative Commons Lizenzvertrag
Dieses Werk ist lizenziert unter einer Creative Commons Namensnennung 4.0 International Lizenz
Fachbereich / Einrichtung:Medizinische Fakultät
Dokument erstellt am:09.03.2026
Dateien geändert am:09.03.2026
english
Benutzer
Status: Gast
Aktionen